Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
en:services:storage_services:backup:tsm:admin:errorcodes [2019/03/13 09:41]
bnachtw [KEY = FF]
en:services:storage_services:backup:tsm:admin:errorcodes [2019/05/02 10:41] (current)
bnachtw [ANR8460E]
Line 10: Line 10:
 |  ASC=2A, ASCQ=03 ​  | SCSI reservation error because several TSM instances use the same persisten name | [[https://​www-01.ibm.com/​support/​docview.wss?​uid=swg1IT03879]] | |  ASC=2A, ASCQ=03 ​  | SCSI reservation error because several TSM instances use the same persisten name | [[https://​www-01.ibm.com/​support/​docview.wss?​uid=swg1IT03879]] |
 |  ASC=29 , ASCQ=00 ​ | "​Power-on,​ reset, bus reset" | [[https://​www-01.ibm.com/​support/​docview.wss?​uid=swg1IT20573]] | |  ASC=29 , ASCQ=00 ​ | "​Power-on,​ reset, bus reset" | [[https://​www-01.ibm.com/​support/​docview.wss?​uid=swg1IT20573]] |
 +
 +==== KEY = FF  ====
 +===== ANR8460E =====
 +  ANR8460E AUDIT LIBRARY process for library <Library Name> failed.
 +
 +^ in combination with ^ possible reason ^ solution ^
 +| ''​ANR9024E There are no drives available.''​ | at least one drive is not available | check drives and make **all** available |
 +| ::: | ::: | check if drives are rotten and if so, remove their definition and paths **completely** |
 +
 +
  
 ===== ANR8840E ===== ===== ANR8840E =====
Line 17: Line 27:
  
  
 +==== error number 11  ==== 
 +^  PVRRC  ^ Meaning ​ ^ Source ^ Solution ^ 
 +|  2845  | Unable to open device <​DEVICE>​ |  ''​audit library''​ failed after drives / paths got unavailable ​ | scsi information mismatch: | 
 +| ::: | ::: | ::: | * reboot server ​ | 
 +| ::: | ::: | ::: | * reboot library ​ | 
 +| ::: | ::: | ::: | * force rescan scsi bus on device layer  | 
 +| ::: | ::: | ::: | * check if the lintape driver is running ;-)  |
  
 ===== ANR8779E ===== ===== ANR8779E =====