   ANR8460E AUDIT LIBRARY process for library <Library Name> failed.   ANR8460E AUDIT LIBRARY process for library <Library Name> failed.
  
-^ in combination with ^ possible reason ^ solution ^ +^ in combination with ^ possible reason ^ solution ^ 
- ''​ANR9024E'' ​ | ''​There are no drives available.''​ | drive is not availble ​| check drives and make **all** available|+| ''​ANR9024E There are no drives available.''​ | at least one drive is not available ​| check drives and make **all** available ​
 +| ::: | ::: | check if drives are rotten and if so, remove their definition and paths **completely** ​|
  
  
Line 33: Line 34:
 | ::: | ::: | ::: | * force rescan scsi bus on device layer  | | ::: | ::: | ::: | * force rescan scsi bus on device layer  |
 | ::: | ::: | ::: | * check if the lintape driver is running ;-)  | | ::: | ::: | ::: | * check if the lintape driver is running ;-)  |
-| ::: | ::: | ::: | * check if one drive is rotten and if so, remove it's definition completely | 
  